Commercial Automated Door Opener 4300

For busy employees, to assist disabled individuals, or for anyone who finds a closed door a problem... automatic door openers can make comings and going easier.

No modification of the door or jambs is required for either unit. The 4300 plugs directly into a standard wall outlet. Complete instructions are packed with every unit. Designed for versatility, these openers fit most interior and exterior doors. Left and right hand units are available, in jamb or door mount. If there isn’t enough room above the door, low profile designs may also accommodate.

The 4300 can be activated by a remote wired or wireless signal. For your convenience, we’ve developed an array of controls adapted for special needs. Choose from push button or push plate wall styles, and wireless coded radio-controlled switches or specialty sip or puff controls.

Features & Benefits

Installation Ease

  • No modification of the door or jambs
  • Plugs right into a regular 115vac wall outlet
  • Complete instructions are packed with every door opener
  • Virtually maintenance free (a couple of drops of oil and a bit of grease every year is all it takes)

Versatile Applications

  • Fits in most interior and some exterior door applications
  • Left and right hand door openers are available
  • Jamb mount, to push door open or door mount, to pull door open
  • Inverted model, for limited room above the door
  • Deep reveal and door mounted door opener units for special applications

An Array of Companion Controls

  • Push Plate Wall Switches
  • Push Button Wall Switches
  • Touch Plate Wall Switch
  • Coded Radio Transmitter/Receiver
  • Keyless Entry Systems
  • Electric Door Locks (Strikes)

Built in Safety Features

  • The door operator arm is not attached to the door. Instead, a wheel at the end of the door operator arm rolls against the face of the door, pushing the door open
    The door can always be opened manually from either side without involving the door operator
    Traffic flow is not hindered by the door operator
  • The Power Access opener is always used in conjunction with a conventional manual door closer, either surface-mounted or concealed
  • If the door meets an obstruction during the opening cycle, built-in load sensing circuit automatically stops the door operator arm and returns to the at-rest (closed) position
  • Thermally protected drive motor
  • Adjustable door hold-open time

Specifications

Operation

Electro-mechanical.  Works against a standard closer.  Seven second cycle time.  Adjustable Timed Hold Open feature for 0 to 30 seconds, or a hold open that requires a signal to close.


Physical Application

Jamb-mount, or inverted mount; no physical attachment or arm to door.  Door mount; attached to door with arm pushing against door frame header.


Power

Requires 115vac 60hz 3amp service to receptacle box


Material/Finish

Painted welded steel frame.  ABS plastic housing. Beige or Bronze.


Motor

115vac 60hz permanent split capacitor, thermally protected


Activation

Touch plate, push button, push plate, radio transmitter, mats, or any momentary dry contact signal. Wired or Wireless.


Dimensions

18 1/2" x 8 1/2" x 7"


Weight

19 pounds


PAC Jam Mount Door Openers

Provide Power Access Model 4300 Series door opener, shall comply with ANSI A156.19-2002, "Standard For Power Assist and Low Energy Power Operated Doors." Automatic door opener shall be electro-mechanical, self contained and mounted to the push side of jamb. The door operator wheeled arm shall not be attached to the door, so that the door may be used in the manual mode as required. The arm shall be driven by a ball screw actuator and take 7 seconds to open (and 7 seconds to close) this speed to accommodate slower moving disabled traffic. The door opener shall have an adjustable sensitivity control so the door will stop if it meets an obstruction during the opening cycle and then recycle closed. The door opener shall have an external on/off switch and an adjustable timed hold open feature from 0 –30 seconds. It shall have an externally accessible circuit breaker to allow resetting in the event of an overload surge. It shall have a built-in line filter to suppress ac line transients and RFI. Door operator requires 115 vac 60 Hz 3 amp service at header location. Door operators shall have a powder painted welded steel frame, fire retardant acrylic/PVC thermoplastic cover (meets UL 94V-0). (Available in beige or dark bronze.)

The door operator shall be mounted according to drawings and instructions provided with each door opener, and used in conjunction with a conventional manual door closer, either of the surface mounted or concealed type. The closer controls the door when it is opened manually and when ever it is closing. Opener shall be compatible with wired or wireless remote controls and with electric strikes.


PAC Door Mount Door Opener

Provide Power Access Model 4300 Series door opener, shall comply with ANSI A156.19-2002, "Standard For Power Assist and Low Energy Power Operated Doors." Automatic door opener shall be electro-mechanical, self contained and mounted to the pull side of the door. The door operator wheeled arm shall be lined up with the header of the door frame, so that the door may be used in the manual mode as required. The arm shall be driven by a ball screw actuator and take 7 seconds to open (and 7 seconds to close) this speed to accommodate slower moving disabled traffic. Clearance behind the opened door must be at least 8 ¸" to permit a full 90 degree opening of the door. The door opener shall have an adjustable sensitivity control so the door will stop if it meets an obstruction during the opening cycle and then recycle closed. The door opener shall have and external on/off switch and an adjustable timed hold open feature from 0 30 seconds. . It shall have an externally accessible circuit breaker to allow resetting in the event of an overload surge. It shall have a built-in line filter to suppress ac line transients and RFI. Door operator requires 115 vac 60 Hz 3 amp service at header location.Door operators shall have a powder painted welded steel frame, fire retardant acrylic/PVC thermoplastic cover (meets UL 94V-0). (Available in beige or dark bronze.)

The door operator shall be mounted according to drawings and instructions provided with each door opener, and used in conjunction with a conventional manual door closer, either of the surface mounted or concealed type. The closer controls the door when it is opened manually and when ever it is closing. Opener shall be compatible with wired or wireless remote controls and with electric strikes.

Online Manuals

The following manuals are available in PDF format. You will need Adobe Acrobat Reader to view.

Assistive Technology

We can help you identify the right products based on your individual needs. Inquire online or give us a call at 1-800-933-8400.

Inquire »

ADA Compliance

We help public facilities comply with the Americans with Disabilities Act for Door Automation. Give us a call at 1-800-933-8400 or inquire online.

Inquire »

Satisfied Customers

"It's so good to be able to do so much by myself again. I have a new sense of independence."

Mr. Owens uses an ECU and Residential Automatic Door Opener to perform many functions he previously needed help to achieve.

Read More »

Stay Informed

Sign up for our free newsletter and recieve helpful product maintenance updates and other important accessibility information..

Sign Up Now »

Hospitals

Give your patients the ability to self-control their environment including telephone, bed, nurse call and television as well as communicate with clinic staff and others using appropriate input method of either single switch, dual switch, voice, head tracking or eye pupil movement.

Learn More »